Laser operation:
 
Q Switched Yag Laser Applications:
 remove red, brown, blue, black tattoo inks,tattoo eyebrows ,lips,body
tattoo.remove speckles, birth marks, blue and brown pigment with pathological changes .lentigines , traumatic pigment; Age spots Pigmentation. Vascular pigmentation removal.
The question:
1.about the possible side effect.
Possible side effects include blistering and crusting after the treatment, hyperpigmentation andhypopigmentation.
2.the customer feel when treatment.
For laser treatment of tattoos, the client will feel a bit heat but not painful which ensures patient ‘scomfort during the treatment. The patient is placed in a comfortable, relaxed position. The Q Switched ND:Yag Laser handpiece is applied to the skin to deliver the laser light. The client is required to wear eyelid patch toprotect the eyes from light.
3.the pre-treatment procedures.
The beautician will consult with you and review the pre-treatment procedures. The treatment skinmust Not be tanned. If the patient has a history of cold sores in the area to be treated, a physicianshould give a prescription for an anti-viral medication. Take the medication pre-treatment andpost-treatment.  Patients who have had Accutane for acne should not take laser treatment for atleast six months (and possibly one year) after stopping Accutane.
4.treatment time.
The length of this treatment varies depending on the size of the area being treated. A few agespots may require a couple of minutes; a large tattoo may require 30 minutes or longer. Largeareas need treating step by step.
5.How many treatments will I need?
Light pigment like freckles, age spots and sun marks could be dispelled by one treatment. Most ofpigment could be dispelled no more than two times. But to some clinically difficulties like thenevus zygomaticus and the nevus of Ota, it will take 3-6 times to complete. Tattoo removal needsabout 2-5 times regarding different colors and tattoo inks.
6.take care of your skin.
The treated skin becomes red immediately after the procedure. Some pigment dispelled on thespot. Some redness and crusting may last for 5-14 days.
Some patients are asked to apply antibiotic ointment and a band aid to the treated area for one totwo weeks. It is important to protect all skin from the sun by using sunblock with a SPF of 30 orabove every day.
 
Treatment
Using Q Switch Nd:YAG impulse laser to remove pigmentation and vascular skin disease will obtain accurate treatment with no untoward effect .The unit is easy to operate with safequalification . After treatment there will be probabilities as follows:
1. In view of variations of categories, locations, seriousness, individual difference and previous treatment, several courses of treatment are needed accordingly; the colour of the affected area will fade gradually.
2. Within and after treatment, there would occur momentary aching. The treated area probably occurs blisters or colour spots, blood effusion, and scabs, which will disappear within one or two weeks.
3. Before recovery, take care of treated area by keeping away from water and cosmetics.Scratching, squeezing and blazing under the sun are strictly prohibited for fear of infect. In case of being infected, use antibiotic paste on affected area once every day. Do not drink alcohol or take aspirin within the first two or three weeks after treatment. The pathological change after treatment is a lasting course of biology. It normally takes 1-3 months. Re-treatment should be given 2-3 months after.
4. Chromotosis probably occur on a few patients, which would vanish in 3-6 months. To avoid chromotosis, use sunblock during the whole treatment.
5. If got infected or any other symptom, go for a consultancy
Precautions
1. The lifetime of xenon lamp in the unit it is lasting about 1000 hours. If working exceeding the lifetime, laser energy would decrease, at this time it is advised to replace it with a new one.
2. Keep the treatment clean and ventilated, when temperature bellows 0 degree, precautions be needed for freezing proofing of the optical devices within the laser.
3. When light path system being fixed up after adjustment, never dismantle any components of the machine or have it re-adjusted. The laser gun should be carefully kept from impact.
4. Never pile up articles as medicine, medical apparatus on the surface of the machine, and keep clean of it.
5. Take away the power keys after using. Only the persons in charge are allowed for operating and safeguarding of the machine. The person is prohibited to use the machine if he does not know how to operate.
6. In case of an accident or the machine working abnormally, immediately turn off the sole switch and press the emergency button to disconnect power.
Lens cleaning
When laser energy decreases, check if the focus lens is contaminated. If so, take the lens out andclean it with 95% alcohol. Never damage the surface of the lens, otherwise please contact withour company for replacement immediately.